IXARC Absolute Rotary Encoder
UCD-CA01B-1412-HGTS-H2M
POSITAL
Measuring Tools & Sensors
CANopen, Multiturn - 14 bit (16384 rev), 12 bit (4096 Steps; 0.088°), IP67, Aluminum / Steel, Blind Hollow Shaft - BC ø 63 mm, 1xTether, ø 58 mm (2.28"), ø 16 mm (0.63"), Connection Cap - 2 x M20 Cable Glands, ≤ 0.09° (Magnetic - Hall Effect), CE / UL
Available
0
Interface | |
Interface | CANopen |
Profile | DS-406 |
Features | Round Axis |
Transmission Rate | min. 20 kBaud, max. 1 MBaud |
Interface Cycle Time | ≥ 1 ms |
Video Manual | Watch a simple installation video |
Programming Functions | Resolution, preset, 2 limit switches, 8 CAMS, baud rate, CAN-Identifier, bootloader, transmission modes: polled, cyclic, sync |
Outputs | |
Output Driver | Transceiver (ISO 11898), Galvanically Isolated by Opto-Couplers |
Electrical Data | |
Supply Voltage | 9 – 30 VDC |
Current Consumption | ≤ 65 mA @ 10 V DC, ≤ 60 mA @ 24 V DC |
Power Consumption | ≤ 1.2 W |
Reverse Polarity Protection | Yes |
Short Circuit Protection | Yes |
EMC: Emitted Interference | DIN EN 61000-6-4 |
EMC: Noise Immunity | DIN EN 61000-6-2 |
MTTF | 240 years @ 40 °C |
Sensor | |
Technology | Magnetic |
Resolution Singleturn | 12 bit |
Resolution Multiturn | 14 bit |
Multiturn Technology | Self powered magnetic pulse counter (no battery, no gear) |
Accuracy (INL) | ±0.0878° (≤ 12 bit) |
Code | Binary |
Environmental Specifications | |
Protection Class (Shaft) | IP66/IP67 |
Protection Class (Housing) | IP66/IP67 |
Operating Temperature | -40 °C (-40 °F) - +85 °C (+185 °F) |
Storage Temperature | -40 °C (-40 °F) – +85 °C (+185 °F) |
Humidity | 98% RH, no condensation |
Mechanical Data | |
Connection Cap Material | Aluminum |
Housing Material | Steel |
Housing Coating | Cathodic corrosion protection (>720 hrs salt spray resistance) |
Flange Type | Blind Hollow, ø 58 mm (H) |
Flange Material | Aluminum |
Shaft Type | Blind Hollow, Depth = 28 mm |
Shaft Diameter | ø 16 mm (0.63") |
Shaft Material | Stainless Steel V2A (1.4305, 303) |
Rotor Inertia | ≤ 30 gcm² [≤ 0.17 oz-in²] |
Friction Torque | ≤ 5 Ncm @ 20 °C, (7.1 oz-in @ 68 °F) |
Max. Permissible Mechanical Speed | ≤ 3000 1/min |
Shock Resistance | ≤ 100 g (half sine 6 ms, EN 60068-2-27) |
Permanent Shock Resistance | ≤ 10 g (half sine 16 ms, EN 60068-2-29) |
Vibration Resistance | ≤ 10 g (10 Hz – 1000 Hz, EN 60068-2-6) |
Length | 89 mm (3.50") |
Weight | 545 g (1.20 lb) |
Maximum Axial / Radial Misalignment | Static ± 0.3 mm /± 0.5 mm; Dynamic ± 0.1 mm /± 0.2 mm |
Electrical Connection | |
Connection Orientation | Radial |
Connection Type | 2 x M20 Cable Glands |
Product Life Cycle | |
Product Life Cycle | New |
|
Connection Plan | |
SIGNAL | PIN NUMBER |
Power Supply | + |
GND | - |
CAN High | H |
CAN Low | L |
CAN GND | G |
CAN High | H |
CAN Low | L |
CAN GND | G |
Connector-View on Encoder
If the drawings are not available please refer to the "Download" section.
The picture and drawing are for general presentation purposes only. All dimension in [inch] mm.
© FRABA B.V., All rights reserved. We do not assume responsibility for technical inaccuracies or omissions. Specifications are subject to change without notice.