POSITAL
Incorrect email or password. Please try again.
Print Send as Email

TILTIX Inclinometer

ACS-090-2-CA01-HE3-PM

POSITAL Measuring Tools & Sensors CANopen, 2 Axes - ± 90°, Static / Accelerometer, CE, IP67, Fibre-Reinforced Plastic, 0.10°, 0.01°, Connector - M12 (5 pin) Available 0
picture-m-1p3-47x52-pm.jpg
General Specifications
Application2-Axes Position Monitoring and Leveling
Measurement Range± 90°
Absolute Accuracy±0.10°
Resolution0.01°
Cycle Time Base Sensor500 µs
Device OrientationHorizontal

Electrical Specifications
Supply Voltage10 – 30 VDC
Current Consumption≤ 65 mA @ 10 V DC, ≤ 60 mA @ 24 V DC
EMC: Emitted InterferenceDIN EN 61000-6-4
EMC: Noise ImmunityDIN EN 61000-6-2
Reverse Polarity ProtectionYes
Short Circuit ProtectionYes
MTTF350 years @ 40 °C
Environmental Specifications
Operating Temperature-40 °C (-40 °F) - +85 °C (+185 °F)
Storage Temperature-40 °C (-40 °F) – +85 °C (+185 °F)
Temperature Gradient0.004°/ K
Protection ClassIP66/IP67
Shock Resistance≤ 100 g (half sine 6 ms, EN 60068-2-27)
Vibration Resistance1.5 mm (10 Hz – 58 Hz) & ≤ 20 g (58 Hz to 2000 Hz)
Mechanical Specifications
Housing MaterialFibre-Reinforced PBT (Polybutylene Terephthalate)
Potting MaterialNone
Weight45 g (0.10 lb)
Interface
InterfaceCANopen
Settling Timemin 30 ms; default 200 ms (dependent on filter settings)
Output DriverTransceiver (ISO 11898), Galvanically Isolated by Opto-Coupl
ProfileDS-410
Transmission Ratemin. 20 kBaud, max. 1 MBaud
Default Transmission Rate125 kBaud
Default Node ID1h
Electrical Connection
Connection TypeConnector M12 (5 pin)
ConnectorM12, Male, 5 pin, a coded
Product Life Cycle
Product Life CycleNew
Certification
ApprovalCE
Connection Plan
SIGNALPIN NUMBER
Power Supply2
GND3
CAN High4
CAN Low5
CAN GND1
Dimensional Drawing
drawing-1p3-47x52-pm.png
2D Drawing

All dimension in [inch] mm. This drawing and the information contained is for general presentation purposes only. Please refer to the "Download" section for detailed technical drawings.

© FRABA B.V., All rights reserved. We do not assume responsibility for technical inaccuracies or omissions. Specifications are subject to change without notice.