POSITAL
Incorrect email or password. Please try again.
Print Send as Email

TILTIX Inclinometer

AGS030-2-SV1-H0-P8M

POSITAL Measuring Tools & Sensors Analog - Voltage 0.5-4.5 V + RS232, 2 Axes - ± 30°, Fluid Cell, CE, IP67, Aluminum, 0.02°, 0.01°, Connector - M12 (5 pin) Available 0
This is a discontinued product!
picture-f-1a3-70x84-pm.jpg
General Specifications
Application2-Axes Position Monitoring and Leveling
Measurement Range± 30°
Absolute Accuracy±0.02°
Resolution0.01°
Electrical Specifications
Supply Voltage10 – 30 VDC
Current Consumption≤ 100 mA @5V, ≤ 45 mA @10V, ≤ 25 mA @24V
EMC: Emitted InterferenceDIN EN 61000-6-4
EMC: Noise ImmunityDIN EN 61000-6-2
Reverse Polarity ProtectionYes
Short Circuit ProtectionYes
MTTF300 years
Environmental Specifications
Operating Temperature-40 °C (-40 °F) - +85 °C (+185 °F)
Storage Temperature-40 °C (-40 °F) – +85 °C (+185 °F)
Temperature Gradient0.003°/ K
Protection ClassIP66/IP67
Shock Resistance≤ 300 g (half sine 6 ms, EN 60068-2-27)
Vibration Resistance10 – 150 Hz, 2.5 mm amplitude, 5 g const. Acceleration
Mechanical Specifications
Housing MaterialAluminum
Weight370 g (0.82 lb)
Interface
InterfaceAnalog Voltage 0.5-4.5 V + RS232
Output TypeVoltage 0.5 – 4.5 V
Output DriverRS232
Min Load Resistance300 Ω
Transmission RateRS232: min. 2400 Baud; max. 57600 Baud
Default Transmission RateRS232: 9600 Baud
Linearity± 0.02%
Electrical Connection
Connection TypeConnector M12 (5 pin)
ConnectorM12, Male, 8 pin, a coded
Product Life Cycle
Product Life CycleDiscontinued
Dimensional Drawing
drawing-1a3-70x84-pm.png
2D Drawing

All dimension in [inch] mm. This drawing and the information contained is for general presentation purposes only. Please refer to the "Download" section for detailed technical drawings.

© FRABA B.V., All rights reserved. We do not assume responsibility for technical inaccuracies or omissions. Specifications are subject to change without notice.