TILTIX Inclinometer
AKS-180-E-CA01-HK2-PV
POSITAL Measuring Tools & Sensors CANopen, Pitch, Roll - ± 85°/± 180° horizontal mounting, Dynamic / Accelerometer + Gyroscope, CE, IP68 / IP69K, Aluminum, 0.30°, 0.01°, Connector - M12 (5 pin) Available 0General Specifications | |
Application | Dynamic Inclinometer 2-Axes with Pitch and Roll |
Measurement Range | Pitch ± 85°, Roll ± 180° |
Absolute Accuracy | ±0.30° |
Resolution | 0.01° |
Repeatability | ≤0.05° |
Dynamic Accuracy | ±0.50° |
Cycle Time Base Sensor | 5 ms |
Hysteresis | ≤0.05° |
Device Orientation | Horizontal |
Electrical Specifications | |
Supply Voltage | 9 – 30 VDC |
Current Consumption | ≤ 65 mA @ 10 V DC, ≤ 60 mA @ 24 V DC |
EMC: Emitted Interference | DIN EN 61000-6-4 |
EMC: Noise Immunity | DIN EN 61000-6-2 |
Reverse Polarity Protection | Yes |
Short Circuit Protection | Yes |
MTTF | 260 years @ 40 °C |
Environmental Specifications | |
Operating Temperature | -40 °C (-40 °F) - +75 °C (+167 °F) |
Storage Temperature | -40 °C (-40 °F) – +85 °C (+185 °F) |
Temperature Gradient | 0.008°/ K |
Protection Class | IP68/IP69K |
Shock Resistance | ≤ 100 g (half sine 6 ms, EN 60068-2-27) |
Vibration Resistance | 1.5 mm (10 Hz – 58 Hz) & ≤ 20 g (58 Hz to 2000 Hz) |
Mechanical Specifications | |
Housing Material | Die-Cast Aluminum Alloy |
Potting Material | PUR (Polyurethane) |
Weight | 220 g (0.49 lb) |
Interface | |
Interface | CANopen |
Settling Time | 50 ms |
Output Driver | Transceiver (ISO 11898), Galvanically Isolated by Opto-Coupl |
Profile | DS-410 |
Transmission Rate | min. 20 kBaud, max. 1 MBaud |
Default Transmission Rate | 125 kBaud |
Default Node ID | 1h |
Electrical Connection | |
Connection Type | Connector M12 (5 pin) |
Connector | M12, Male, 5 pin, a coded |
Product Life Cycle | |
Product Life Cycle | Established |
Certification | |
Approval | CE + E1 |
Connection Plan | |
SIGNAL | PIN NUMBER |
Power Supply | 2 |
GND | 3 |
CAN High | 4 |
CAN Low | 5 |
CAN GND | 1 |
Dimensional Drawing
2D DrawingAll dimension in [inch] mm. This drawing and the information contained is for general presentation purposes only. Please refer to the "Download" section for detailed technical drawings.
© FRABA B.V., All rights reserved. We do not assume responsibility for technical inaccuracies or omissions. Specifications are subject to change without notice.