LINARIX Linear Sensor
LU0-CA01B-1213-5G00-CAW
POSITAL
Measuring Tools & Sensors
IP64 / IP65, Draw Wire - 3 m – 6.9 m (9.84' – 22.63'), CANopen, 13 bit (8192 Steps), Draw Wire Enclosure - Extruded Metal, Cable - Axial 1 m, Radial 0 / Axial, Magnetic (≤ 0.09°)
Available
0
General Data Supply Voltage 9 – 30 VDC Power Consumption ≤ 1.2 W Operating Temperature -20 °C (-4 °F) - +80 °C (+176 °F) Weight 1480 g (3.26 lb) Protection Class (Encoder) IP64 / IP65 EMC: Emitted Interference DIN EN 61000-6-4 EMC: Noise Immunity DIN EN 61000-6-2
Mechanical Data Max. Measurement Length 5.00 m (16.40') Length per Revolution 315 mm Wire Material Coated Polyamide Stainless Steel Wire Diameter 1.00 mm Encoder Housing Material Steel Draw Wire Housing Material Aluminum Max. Speed of Wire Displacement 2.0 m / s Max. Wire Acceleration 5.0 g Max. Extension Force 16.0 N Min. Retraction Force 4.0 N Actuation Lifetime 0.5 mio Cycles (Estimated based on ideal conditions) Wire Mounting Eyelet Max. Wire Exit Angle ±3°
Sensor Data Technology Magnetic (≤ 0.09°) Accuracy ±0.02 % FSO Repeatability ±0.002 % FSO Resolution [Encoder - Singleturn] 13 bit Resolution [Encoder - Multiturn] 12 bit Approx. Linear Resolution 38.5 µm Output Code Binary
Interface Communication Interface CANopen Profile DS-406 Programming Functions Resolution, preset, 2 limit switches, 8 CAMS, baud rate, CAN-Identifier, bootloader, transmission modes: polled, cyclic, sync Transmission Rate min. 20 kBaud, max. 1 MBaud Cycle Time Interface ≥ 1 ms
Outputs Output Driver Transceiver (ISO 11898), Galvanically Isolated by Opto-Coupl Current Consumption ≤ 70 mA @ 10 V DC, ≤ 50 mA @ 24 V DC Reverse Polarity Protection Yes Short Circuit Protection Yes MTTF 240 years @ 40 °C
Electrical Connection Connection Orientation Axial Connection Orientation (w.r.t Draw Wire) Radial 0 / Axial Connection Type Cable / Connector Cable Length 1 m [39"] Wire Cross Section 0.14 mm² / AWG 26 Material / Type PVC Cable Diameter 6 mm (0.24 in) Minimum Bend Radius 46 mm (1.81") fixed, 61 mm (2.4") flexing
Product Life Cycle Product Life Cycle Established
Connection Plan SIGNAL CABLE COLOR Power Supply Red GND Yellow CAN High White CAN Low Brown CAN GND Green
Connector-View on Encoder
All dimension in [inch] mm. Encoder dimensions may vary depending on electrical interface and connector. This drawing and the information contained is for general presentation purposes only. Please refer to the "Download" section for detailed technical drawings.
© FRABA B.V., All rights reserved. We do not assume responsibility for technical inaccuracies or omissions. Specifications are subject to change without notice.