POSITAL
Incorrect email or password. Please try again.
Print Send as Email

LINARIX Linear Sensor

LD0-S3B1G-1212-AH00-PAL

POSITAL Measuring Tools & Sensors IP64 / IP65, Draw Wire - 7 m – 15 m (22.96' – 49.21'), SSI / SSI + Incremental - Gray + A/B (RS-422), 12 bit (4096 Steps), Draw Wire Enclosure - Extruded Metal, Connector - Axial M23, Radial 0 / Axial, Optical (≤ 0.02°) Available 0
picture-h-5-cax-lx-nnn.png
General Data
General Data
Supply Voltage4.5 – 30 VDC
Power Consumption≤ 1.5 W
Turn On Time< 1 s
Operating Temperature-20 °C (-4 °F) - +80 °C (+176 °F)
Weight3075 g (6.78 lb)
Protection Class (Encoder)IP64 / IP65
EMC: Emitted InterferenceDIN EN 61000-6-4
EMC: Noise ImmunityDIN EN 61000-6-2
Mechanical Data
Max. Measurement Length10.00 m (32.81')
Length per Revolution315 mm
Wire MaterialCoated Polyamide Stainless Steel
Wire Diameter1.00 mm
Encoder Housing MaterialSteel
Draw Wire Housing MaterialAluminum
Max. Speed of Wire Displacement2.0 m / s
Max. Wire Acceleration6.0 g
Max. Extension Force21.0 N
Min. Retraction Force8.0 N
Actuation Lifetime0.5 mio Cycles (Estimated based on ideal conditions)
Wire MountingEyelet
Max. Wire Exit Angle±3°
Sensor Data
TechnologyOptical (≤ 0.02°)
Accuracy±0.01 % FSO
Repeatability±0.001 % FSO
Resolution [Encoder - Singleturn]12 bit
Resolution [Encoder - Multiturn]12 bit
Approx. Linear Resolution76.9 µm
Output CodeGray
Interface
Communication InterfaceSSI with Preset and Incr.
Manual FunctionsPreset + complement via cable or connector
Cycle Time Interface≥ 25 µs
Outputs
Output DriverSSI (RS422) / Incr. (RS422)
Output IncrementalA, /A, B, /B
Quadrature Phasing90° ± 4.5° electrical
Clock InputRS 422, via Optocoupler
Clock frequency100 kHz – 2 MHz
Reverse Polarity ProtectionYes
Short Circuit ProtectionYes
MTTF16.2 years @ 40 °C
Electrical Connection
Connection OrientationAxial
Connection Orientation (w.r.t Draw Wire)Radial 0 / Axial
ConnectorM23, Male, 12 pin, CCW / left
Product Life Cycle
Product Life CycleEstablished
Connection Plan
SIGNALPIN NUMBER
Power Supply11
GND12
Data+3
Data-4
Clock+2
Clock-1
DIR8
Preset9
A5
/A6
B7
/B10
ShieldingShell
Connector-View on Encoder

Pulse Diagram

Dimensional Drawing
drawing-h-5-cax-sx-lx-.png
2D Drawing

All dimension in [inch] mm. Encoder dimensions may vary depending on electrical interface and connector. This drawing and the information contained is for general presentation purposes only. Please refer to the "Download" section for detailed technical drawings.

© FRABA B.V., All rights reserved. We do not assume responsibility for technical inaccuracies or omissions. Specifications are subject to change without notice.