LINARIX Linear Sensor
LD0-S5B1G-1212-2P20-CRW
POSITAL
Measuring Tools & Sensors
IP64 / IP65, Draw Wire - 1 m – 2.9 m (3.28' – 9.51'), SSI / SSI + Incremental - Gray + A/B/Z (RS-422), 12 bit (4096 Steps), Draw Wire Enclosure - Machined Metal - Cylindrical Housing, Cable - Radial 1 m, Radial 2, Optical (≤ 0.02°)
Available
0
General Data Supply Voltage 4.5 – 30 VDC Power Consumption ≤ 1.5 W Turn On Time < 1 s Operating Temperature -20 °C (-4 °F) - +70 °C (+158 °F) Weight 470 g (1.04 lb) Protection Class (Encoder) IP64 / IP65 EMC: Emitted Interference DIN EN 61000-6-4 EMC: Noise Immunity DIN EN 61000-6-2
Mechanical Data Max. Measurement Length 1.90 m (6.23') Length per Revolution 150 mm Wire Material Coated Polyamide Stainless Steel Wire Diameter 0.45 mm Encoder Housing Material Steel Draw Wire Housing Material Aluminum Max. Speed of Wire Displacement 2.0 m / s Max. Wire Acceleration 12.0 g Max. Extension Force 5.0 N Min. Retraction Force 3.5 N Actuation Lifetime 1.0 mio Cycles (Estimated based on ideal conditions) Wire Mounting Eyelet Max. Wire Exit Angle ±3°
Sensor Data Technology Optical (≤ 0.02°) Accuracy ±0.02 % FSO Repeatability ±0.006 % FSO Resolution [Encoder - Singleturn] 12 bit Resolution [Encoder - Multiturn] 12 bit Approx. Linear Resolution 36.6 µm Output Code Gray
Interface Communication Interface SSI with Preset + Incremental RS422 Manual Functions Preset + complement via cable or connector Cycle Time Interface ≥ 25 µs
Outputs Output Driver SSI (RS422) / Incr. (RS422) Output Incremental A, /A, B, /B, Z, /Z Quadrature Phasing 90° ± 4.5° electrical Clock Input RS 422, via Optocoupler Clock frequency 100 kHz – 2 MHz Reverse Polarity Protection Yes Short Circuit Protection Yes MTTF 16.2 years @ 40 °C
Electrical Connection Connection Orientation Radial Connection Orientation (w.r.t Draw Wire) Radial 2 Cable Length 1 m [39"] Wire Cross Section 0.14 mm² / AWG 26 Material / Type PVC Cable Diameter 8 mm (0.31 in) Minimum Bend Radius 35 mm (1.38) fixed, 70 mm (2.76)
Product Life Cycle Product Life Cycle Established
Connection Plan SIGNAL CABLE COLOR Power Supply Brown GND White Data+ Gray Data- Pink Clock+ Green Clock- Yellow DIR Red Preset Blue A Black /A Violet B Gray-Pink /B Red-Blue Z White-Green /Z Brown-Green Shielding Shield
Connector-View on Encoder
Pulse Diagram
Rotation Clockwise (seen on shaft)
All dimension in [inch] mm. Encoder dimensions may vary depending on electrical interface and connector. This drawing and the information contained is for general presentation purposes only. Please refer to the "Download" section for detailed technical drawings.
© FRABA B.V., All rights reserved. We do not assume responsibility for technical inaccuracies or omissions. Specifications are subject to change without notice.